R&D of MOSFET Radiation Monitors

S. Stanic, T. Tsuboyama, D. Zontar, Y. Asano, S. Iwaida
(See also: MPGA based RadFET Reader Module)

Papers

  • Radiation monitoring in MRad range using radiation-sensing field-effect transistors
    NIMA545-252 (2005) pdf

Related Papers

  • D. Zontar et al. Radiation Monitoring at Belle, NIM A 501 164-166 (2003) (pdf)
  • A. Rosenfeld, A system for Radiation Damage Monitoring, IEEE Trans. Nucl. Sci. 46/6 (1999) (pdf)
  • A. Holmes-Siedle, REM's Integrating Dosimeter System Based on the RadFET, REM Tech.Report 98-3 (doc)
  • A. Holmes-Siedle, REM's Integrating Dosimeter System Based on the RadFET, REM Tech.Report 00-1 (doc)

Test hybrids

Other design specifications
  • Test circuit board 2003/04/18 ( pdf, ps, fig)
  • Photos of mounted RadFET chips
  • RadFET pad layout (gif, eps)
  • Test board connection to Wollongong reader (txt)
  • PT100 capton design ( ps, eps)
Prototype for ZEUS/Desy 2004/11/08
  • Description (txt)
  • Bonding scheme (gif)
Irradiation 2004/11/08 Irradiation 2004/04/05 Irradiation 2003/12/17 Irradiation 2003/05/19-2003/05/20 at TIT
  • Experiment description (txt)
  • Data 2003/05/19 - 2003/06/16 (txt)
  • Plots

SVD2.0 sensors

  • Report on RadFET calibration (SVD meeting 2002/08/22) (pdf)
Irradiation 2002/08/29-2002/08/30 and Offline 2002/07->

SVD 1.4 sensors

Irradiation 2002/03/14 Irradiation 2001/09/07